Bronchopleural fistula (BPF) is a rare but fatal complication after pneumonectomy. When a BPF occurs late (weeks to years postoperatively), direct resealing of the bronchial stump through the primary thoracic … Read More
Category: General
Nomogram using intratumoral and peritumoral radiomics for the preoperative prediction of visceral pleural invasion in clinical stage IA lung adenocarcinoma
Accurate prediction of visceral pleural invasion (VPI) in lung adenocarcinoma before operation can provide guidance and help for surgical operation and postoperative treatment. We investigate the value of intr… Read More
Unexpected diagnosis: large hemangioma in the interatrial septum
Cardiac hemangiomas are very uncommon benign primary tumors. They are usually located preferentially in the right atrium and their location in the interatrial septum is extremely rare.
Comparison between one-stage and two-stage CT-guided localization of lung nodules with surgical resection: a single medical center experience
This retrospective study aimed to compare the efficacy and safety of one-stage computed tomography (OSCT)- to that of two-stage computed tomography (TSCT)-guided localization for the surgical removal of small … Read More
Uncommon presentations of type A quadricuspid aortic valve in the Septuagenarian
Quadricuspid aortic valve (QAV) is a rare congenital anomaly characterized by the presence of four cusps instead of the usual three. It is estimated to occur in less than 0.05% of the population, with Type A (… Read More
Fish swim bladders as valve leaflets enhance the durability of transcatheter aortic valve replacement devices
Acta Biomater. 2024 Apr 23:S1742-7061(24)00213-7. doi: 10.1016/j.actbio.2024.04.030. Online ahead of print.
ABSTRACT
Transcatheter aortic valve replacement (TAVR) has emerged as an effective therapy for inoperable patients with severe aortic stenosis (AS). However, calcification-induced limited durability restricts its application. Fish swim bladders (FSB), which are resistant to calcific degeneration, offer a viable solution to this challenge. In this study, we developed a new TAVR device using FSB as the valve leaflet. Furthermore, the in vitro durability, in vivo performance, and size selection of this TAVR device were assessed by an experimental study and finite element analysis. A self-expandable TAVR device was fabricated by suturing the FSB films into a 23 mm nitinol alloy frame. Further, hemodynamic performance, such as effective orifice area, transvalvular pressure difference and regurgitant fraction, the durability was tested by the pulsatile flow test and accelerated fatigue test, according to the ISO 5840-3. The effect of release size on hydrodynamic performance was also investigated. Finally, the in vivo performance of the TAVR device were examined using a porcine implantation model. The results showed that the strength of the FSB films satisfied the requirements for valve leaflets. The hemodynamic performance of the FSB TAVR device met the requirements of ISO 5840-3 standards. After 400 million cycles, the FSB showed no fiber loss, torn, perforation, or other valve failure phenomena. In porcine models, the devices were well-positioned, functioned well with no stenosis immediately after the operation. Collectively, we successfully developed a TAVR device with FSB as valve leaflets that exhibited good fatigue resistance. STATEMENT OF SIGNIFICANCE: The source of material for the leaflets of commercialized biological heart valves (BHVs) is mainly bovine pericardium, but this material suffers the following problems: large and uneven thickness of the material, the presence of α-Gal and Neu5Gc antigens, and the susceptibility to structural valve degradation (SVD). New material for BHVs leaflets is rarely reported. In this study, we prepared a transcatheter aortic valve (TAV) and performed long-term in vitro and short-term in vivo studies using fish swim bladder (FSB) as the leaflets. The study confirmed that FSB TAV device can complete 400 million fatigue tests and maintain the good morphology of the leaflets, and that it still maintains good functionality after a certain amount of compression, indicating that FSB is a promising material for leaflets.
PMID:38663685 | DOI:10.1016/j.actbio.2024.04.030
Retrograde cerebral perfusion reduces embolic and watershed lesions after acute type a aortic dissection repair with deep hypothermic circulatory arrest
To assess whether retrograde cerebral perfusion reduces neurological injury and mortality in patients undergoing surgery for acute type A aortic dissection.
Uncommon presentations of type A quadricuspid aortic valve in the Septuagenarian
Quadricuspid aortic valve (QAV) is a rare congenital anomaly characterized by the presence of four cusps instead of the usual three. It is estimated to occur in less than 0.05% of the population, with Type A (… Read More
Circumferent dissection of the ascending aorta resulting in the occlusion of supra-aortic vessels repaired using the frozen elephant trunk technique – a case report
Our patient presented with acute back pain and dyspnea, without neurological symptoms. The computed tomography (CT) scan showed a circumferent rupture of the ascending aortic intima which was invaginated in th… Read More
Circumferent dissection of the ascending aorta resulting in the occlusion of supra-aortic vessels repaired using the frozen elephant trunk technique – a case report
Our patient presented with acute back pain and dyspnea, without neurological symptoms. The computed tomography (CT) scan showed a circumferent rupture of the ascending aortic intima which was invaginated in th… Read More
