Treatment of late left bronchopleural fistula after left pneumonectomy through right thoracic approach assisted by extracorporeal membrane oxygenation

Bronchopleural fistula (BPF) is a rare but fatal complication after pneumonectomy. When a BPF occurs late (weeks to years postoperatively), direct resealing of the bronchial stump through the primary thoracic …  Read More

Nomogram using intratumoral and peritumoral radiomics for the preoperative prediction of visceral pleural invasion in clinical stage IA lung adenocarcinoma

Accurate prediction of visceral pleural invasion (VPI) in lung adenocarcinoma before operation can provide guidance and help for surgical operation and postoperative treatment. We investigate the value of intr…  Read More

Comparison between one-stage and two-stage CT-guided localization of lung nodules with surgical resection: a single medical center experience

This retrospective study aimed to compare the efficacy and safety of one-stage computed tomography (OSCT)- to that of two-stage computed tomography (TSCT)-guided localization for the surgical removal of small …  Read More

Fish swim bladders as valve leaflets enhance the durability of transcatheter aortic valve replacement devices

Acta Biomater. 2024 Apr 23:S1742-7061(24)00213-7. doi: 10.1016/j.actbio.2024.04.030. Online ahead of print.

ABSTRACT

Transcatheter aortic valve replacement (TAVR) has emerged as an effective therapy for inoperable patients with severe aortic stenosis (AS). However, calcification-induced limited durability restricts its application. Fish swim bladders (FSB), which are resistant to calcific degeneration, offer a viable solution to this challenge. In this study, we developed a new TAVR device using FSB as the valve leaflet. Furthermore, the in vitro durability, in vivo performance, and size selection of this TAVR device were assessed by an experimental study and finite element analysis. A self-expandable TAVR device was fabricated by suturing the FSB films into a 23 mm nitinol alloy frame. Further, hemodynamic performance, such as effective orifice area, transvalvular pressure difference and regurgitant fraction, the durability was tested by the pulsatile flow test and accelerated fatigue test, according to the ISO 5840-3. The effect of release size on hydrodynamic performance was also investigated. Finally, the in vivo performance of the TAVR device were examined using a porcine implantation model. The results showed that the strength of the FSB films satisfied the requirements for valve leaflets. The hemodynamic performance of the FSB TAVR device met the requirements of ISO 5840-3 standards. After 400 million cycles, the FSB showed no fiber loss, torn, perforation, or other valve failure phenomena. In porcine models, the devices were well-positioned, functioned well with no stenosis immediately after the operation. Collectively, we successfully developed a TAVR device with FSB as valve leaflets that exhibited good fatigue resistance. STATEMENT OF SIGNIFICANCE: The source of material for the leaflets of commercialized biological heart valves (BHVs) is mainly bovine pericardium, but this material suffers the following problems: large and uneven thickness of the material, the presence of α-Gal and Neu5Gc antigens, and the susceptibility to structural valve degradation (SVD). New material for BHVs leaflets is rarely reported. In this study, we prepared a transcatheter aortic valve (TAV) and performed long-term in vitro and short-term in vivo studies using fish swim bladder (FSB) as the leaflets. The study confirmed that FSB TAV device can complete 400 million fatigue tests and maintain the good morphology of the leaflets, and that it still maintains good functionality after a certain amount of compression, indicating that FSB is a promising material for leaflets.

PMID:38663685 | DOI:10.1016/j.actbio.2024.04.030

Retrograde cerebral perfusion reduces embolic and watershed lesions after acute type a aortic dissection repair with deep hypothermic circulatory arrest

To assess whether retrograde cerebral perfusion reduces neurological injury and mortality in patients undergoing surgery for acute type A aortic dissection.

Circumferent dissection of the ascending aorta resulting in the occlusion of supra-aortic vessels repaired using the frozen elephant trunk technique – a case report

Our patient presented with acute back pain and dyspnea, without neurological symptoms. The computed tomography (CT) scan showed a circumferent rupture of the ascending aortic intima which was invaginated in th…  Read More

Circumferent dissection of the ascending aorta resulting in the occlusion of supra-aortic vessels repaired using the frozen elephant trunk technique – a case report

Our patient presented with acute back pain and dyspnea, without neurological symptoms. The computed tomography (CT) scan showed a circumferent rupture of the ascending aortic intima which was invaginated in th…  Read More