Iatrogenic aortic regurgitation secondary to leaflet injury is a rare complication of mitral valve surgery. For the first time, we report a patient who had progressive aortic regurgitation due to non-coronary … Read More
Category: General
Co-occurrence of posterior chest wall pilonidal sinus with melanocytic nevus: a challenging presentation: a case report
To date, only a limited number of case reports have documented the co-occurrence of PNS and melanocytic nevus in the medical literature. This study aims to report an exceptionally rare case of posterior chest … Read More
Iatrogenic non-coronary leaflet perforation as a complication after robotic mitral valve repair
Iatrogenic aortic regurgitation secondary to leaflet injury is a rare complication of mitral valve surgery. For the first time, we report a patient who had progressive aortic regurgitation due to non-coronary … Read More
Tissue requirements for the application of aortic valve neocuspidization – appropriate pericardium properties and homogeneity?
J Mater Sci Mater Med. 2024 Apr 29;35(1):26. doi: 10.1007/s10856-024-06790-2.
ABSTRACT
OBJECTIVE: Aortic valve neocuspidization (AVNeo) using autologous pericardium is a promising technique. Expected advantages are reduced immune response, appropriate biomechanics and lower treatment expenses. Nevertheless, autologous pericardium can be affected by patient’s age and comorbidities. Usually, glutaraldehyde (GA) – fixed bovine pericardium is the basic material for aortic valve prostheses, easy available and carefully pre-examined in a standardized fabrication process. Aim of the study is the verification of autologous pericardial tissue homogeneity by analysing tissue thickness, biomechanics and extracellular matrix (ECM) composition.
METHODS: Segments of human GA-fixed pericardium selected by the surgeon based on visual criteria for cusp pre-cut and remaining after surgical AV replacement were investigated in comparison to bovine standard tissue treated equivalently. Pericardium sampling was performed at up to three positions of each sutured cusp for histological or biomechanical analysis, according to tissue availability.
RESULTS AND CONCLUSIONS: Human pericardia exhibited a higher heterogeneity in collagen content, density of vessel structures and elastic moduli. Thickness, vessel density and collagen and elastin content differed significantly between the species. In contrast, significant interindividual differences were detected in most properties investigated for human pericardial samples but only for tissue thickness in bovine tissues. Higher heterogeneity of human pericardium, differing vessel and collagen content compared to bovine state-of-the-art material might be detrimental for long term AV functionality or deterioration and have to be intensely investigated in patients follow up after autologous cusp replacement.
PMID:38683259 | PMC:PMC11058761 | DOI:10.1007/s10856-024-06790-2
Antegrade Aorto-Mesenteric Bypass Using a Prefabricated Bovine Pericardium Tube Graft for the Treatment of Chronic Mesenteric Ischemia Complicated With Intestinal Necrosis and Biliary Peritonitis
Cureus. 2024 Apr 3;16(4):e57530. doi: 10.7759/cureus.57530. eCollection 2024 Apr.
ABSTRACT
Chronic mesenteric ischemia (CMI) is a vascular disorder primarily caused by atherosclerosis, resulting in intestinal ischemia. While endovascular treatment has become the primary modality for most patients, open mesenteric revascularization remains crucial for complex cases. We present a case of CMI in a patient with critical ischemia, leading to small bowel necrosis, where the endovascular recanalization failed and a surgical approach was needed. A supraceliac antegrade aortomesenteric bypass was performed, and successful revascularization of intestinal circulation was achieved. A novel prefabricated bovine pericardium tube was used as a graft, and the bypass was placed behind the pancreas to ensure maximal isolation from the contaminated abdominal cavity. Despite the intestinal revascularization, in the early postoperative period, the overall condition of the patient worsened with obvious signs of peritonitis. The second look operation revealed a ruptured gallbladder with severe biliary peritonitis, likely caused by the preceding splanchnic ischemia. A cholecystectomy, lavage, and drainage were performed. No further intestinal necrosis was observed, and the bowel passage was restored with latero-lateral jejuno-lejunostomy. The follow-up of the patient showed no signs of graft infection. Despite the complications, the patient’s postoperative period was stable, and he was discharged on day sixteen. Regular follow-ups confirmed an excellent patency of the bypass.
PMID:38707110 | PMC:PMC11067987 | DOI:10.7759/cureus.57530
The influence of low-dose s-ketamine on postoperative delirium and cognitive function in older adults undergoing thoracic surgery
Postoperative delirium (POD) and cognitive dysfunction (POCD) are common complications following thoracic surgery, particularly in patients aged 65 years and above. These complications can significantly affect… Read More
Challenges in prompt identification and surgical correction of Marfan Syndrome aortic disease in a middle-income country: a case series study
Marfan Syndrome is an autosomal dominant disease caused by pathogenetic variants in the FBN1 gene. The progressive dilatation of the aorta and the potential risk of acute aortic syndromes influence the prognos… Read More
The influence of low-dose s-ketamine on postoperative delirium and cognitive function in older adults undergoing thoracic surgery
Postoperative delirium (POD) and cognitive dysfunction (POCD) are common complications following thoracic surgery, particularly in patients aged 65 years and above. These complications can significantly affect… Read More
A rare case of left atrial appendage aneurysm
Left atrial appendage aneurysm is a rare cardiac mass, with only a few cases reported. There are usually no specific symptoms, and a few patients visit the doctor with symptoms.
Endovascular repair for thoracic aortic pseudoaneurysm induced by pedicle screw implantation: a case report with 8 years follow-up
Pedicle screw instrument surgeries can result in the development of aortic pseudoaneurysm, which is a rare yet potentially severe complication; therefore, the purpose of this work is to describe the case of ps… Read More