Stents versus bypass surgery: 3-year mortality risk of patients with coronary interventions aged 50+ in Germany

Due to demographic aging, the prevalence of coronary artery disease (CAD) is expected to increase in the future, resulting in a growing demand for stent and bypass interventions. This study aims to investigate…  Read More

Technical Aspects and Development of Transcatheter Aortic Valve Implantation

J Cardiovasc Dev Dis. 2022 Aug 22;9(8):282. doi: 10.3390/jcdd9080282.

ABSTRACT

Aortic stenosis is the most common valve disease requiring surgery or percutaneous treatment. Since the first-in-man implantation in 2002 we have witnessed incredible progress in transcatheter aortic valve implantation (TAVI). In this article, we review the technical aspects of TAVI development with a look at the future. Durability, low thrombogenicity, good hydrodynamics, biocompatibility, low catheter profile, and deployment stability are the attributes of an ideal TAVI device. Two main design types exist-balloon-expandable and self-expanding prostheses. Balloon-expandable prostheses use a cobalt-chromium alloy frame providing high radial strength and radiopacity, while the self-expanding prostheses use a nickel-titanium (Nitinol) alloy frame, which expands to its original shape once unsheathed and heated to the body temperature. The valve is sewn onto the frame and consists of the porcine or bovine pericardium, which is specially treated to prevent calcinations and prolong durability. The lower part of the frame can be covered by polyethylene terephthalate fabric or a pericardial skirt, providing better sealing between the frame and aortic annulus. The main future challenges lie in achieving lower rates of paravalvular leaks and new pacemaker implantations following the procedure, lower delivery system profiles, more precise positioning, longer durability, and a good hemodynamic profile. Patient-specific design and the use of autologous tissue might solve these issues.

PMID:36005446 | PMC:PMC9409777 | DOI:10.3390/jcdd9080282

Localization of small peripheral pulmonary nodules for surgical resection: a new intraoperative technique in hybrid operating room

The purpose of this study was to introduce a new feasible and effective intraoperative localization technique for small peripheral pulmonary nodules in hybrid operating room.

Aneurysmal degeneration of the hood of a cryopreserved vein allograft two years after thrombosis

J Vasc Surg Cases Innov Tech. 2022 May 3;8(2):300-304. doi: 10.1016/j.jvscit.2022.04.002. eCollection 2022 Jun.

ABSTRACT

Cryopreserved vein allografts are used as alternative conduits for infrainguinal bypass but are prone to aneurysmal degeneration. A 60-year-old man presented with a pulsatile, tender right groin mass 2 years after thrombosis of a cryopreserved vein jump graft emanating from a prosthetic axillary to profunda bypass. Intraoperatively, the aneurysm was consistent with isolated dilatation of the hood of the thrombosed cryopreserved vein graft. This was excised and repaired with bovine pericardial patch angioplasty. The patient recovered with no recurrence for 2 years. Aneurysmal degeneration of the cryopreserved vein allograft can occur even after graft thrombosis.

PMID:35669278 | PMC:PMC9166410 | DOI:10.1016/j.jvscit.2022.04.002

Successful treatment with femoro-femoral venovenous extracorporeal membrane oxygenation in traumatic tracheal injury: a case report

Traumatic tracheal injury is a rare type of trauma. In this type of injury, catastrophes may occur owing to a failure to secure the patient’s airway. Extracorporeal membrane oxygenation (ECMO) is rescue therap…  Read More