Comparison of erector spinae plane block with paravertebral block for thoracoscopic surgery: a meta-analysis of randomized controlled trials

The efficacy of erector spinae plane block versus paravertebral block for thoracoscopic surgery remains controversial. We conduct a systematic review and meta-analysis to explore the impact of erector spinae p…  Read More

Surgical treatment of left ventricular aneurysm in patients with prior myocardial infarction in the absence of obstructive coronary artery disease (MINOCA): a cohort study

There is a paucity of studies examining the treatment of patients with prior myocardial infarction in the absence of obstructive coronary arteries (MINOCA) and with a concomitant left ventricular aneurysm. Our…  Read More

Comparison of erector spinae plane block with paravertebral block for thoracoscopic surgery: a meta-analysis of randomized controlled trials

The efficacy of erector spinae plane block versus paravertebral block for thoracoscopic surgery remains controversial. We conduct a systematic review and meta-analysis to explore the impact of erector spinae p…  Read More

Performance of xenogeneic pulmonary visceral pleura as bioprosthetic heart valve cusps in swine

Front Cardiovasc Med. 2023 Aug 2;10:1213398. doi: 10.3389/fcvm.2023.1213398. eCollection 2023.

ABSTRACT

OBJECTIVE: Bovine pericardium is common biological material for bioprosthetic heart valve. There remains a significant need, however, to improve bioprosthetic valves for longer-term outcomes. This study aims to evaluate the chronic performance of bovine pulmonary visceral pleura (PVP) as bioprosthetic valve cusps.

METHODS: The PVP was extracted from the bovine lung and fixed in 0.625% glutaraldehyde overnight at room temperature. The PVP valve cusps for the bioprosthetic valve were tailored using a laser cutter. Three leaflets were sewn onto a nitinol stent. Six PVP bioprosthetic valves were loaded into the test chamber of the heart valve tester to complete 100 million cycles. Six other PVP bioprosthetic valves were transcardially implanted to replace pulmonary artery valve of six pigs. Fluoroscopy and intracardiac echocardiography were used for in vivo assessments. Thrombosis, calcification, inflammation, and fibrosis were evaluated in the terminal study. Histologic analyses were used for evaluations of any degradation or calcification.

RESULTS: All PVP bioprosthetic valves completed 100 million cycles without significant damage or tears. In vivo assessments showed bioprosthetic valve cusps open and coaptation at four months post-implant. No calcification and thrombotic deposits, inflammation, and fibrosis were observed in the heart or pulmonary artery. The histologic analyses showed complete and compact elastin and collagen fibers in the PVP valve cusps. Calcification-specific stains showed no calcific deposit in the PVP valve cusps.

CONCLUSIONS: The accelerated wear test demonstrates suitable mechanical strength of PVP cusps for heart valve. The swine model demonstrates that the PVP valve cusps are promising for valve replacement.

PMID:37600031 | PMC:PMC10433919 | DOI:10.3389/fcvm.2023.1213398

Performance of xenogeneic pulmonary visceral pleura as bioprosthetic heart valve cusps in swine

Front Cardiovasc Med. 2023 Aug 2;10:1213398. doi: 10.3389/fcvm.2023.1213398. eCollection 2023.

ABSTRACT

OBJECTIVE: Bovine pericardium is common biological material for bioprosthetic heart valve. There remains a significant need, however, to improve bioprosthetic valves for longer-term outcomes. This study aims to evaluate the chronic performance of bovine pulmonary visceral pleura (PVP) as bioprosthetic valve cusps.

METHODS: The PVP was extracted from the bovine lung and fixed in 0.625% glutaraldehyde overnight at room temperature. The PVP valve cusps for the bioprosthetic valve were tailored using a laser cutter. Three leaflets were sewn onto a nitinol stent. Six PVP bioprosthetic valves were loaded into the test chamber of the heart valve tester to complete 100 million cycles. Six other PVP bioprosthetic valves were transcardially implanted to replace pulmonary artery valve of six pigs. Fluoroscopy and intracardiac echocardiography were used for in vivo assessments. Thrombosis, calcification, inflammation, and fibrosis were evaluated in the terminal study. Histologic analyses were used for evaluations of any degradation or calcification.

RESULTS: All PVP bioprosthetic valves completed 100 million cycles without significant damage or tears. In vivo assessments showed bioprosthetic valve cusps open and coaptation at four months post-implant. No calcification and thrombotic deposits, inflammation, and fibrosis were observed in the heart or pulmonary artery. The histologic analyses showed complete and compact elastin and collagen fibers in the PVP valve cusps. Calcification-specific stains showed no calcific deposit in the PVP valve cusps.

CONCLUSIONS: The accelerated wear test demonstrates suitable mechanical strength of PVP cusps for heart valve. The swine model demonstrates that the PVP valve cusps are promising for valve replacement.

PMID:37600031 | PMC:PMC10433919 | DOI:10.3389/fcvm.2023.1213398

Severe Tricuspid Regurgitation in a Patient With Previous Tricuspid Valve Surgery for Infective Endocarditis Secondary to Intravenous Drug Use: A Case Report

Cureus. 2023 Jun 16;15(6):e40497. doi: 10.7759/cureus.40497. eCollection 2023 Jun.

ABSTRACT

Tricuspid regurgitation (TR) is an important but underappreciated disease in medical practice, and the severity can vary from moderate to severe. Right-sided infective endocarditis (RSIE) is more common in intravenous drug users (IVDUs), and the vast majority of these involve the tricuspid valve (TV). It is worth mentioning that right-sided valves are challenging to scan compared to left-sided valves. The incidence of severe tricuspid regurgitation (TR) immediately post-repair is not tangible, but it is considered to be rare. We present a case of a 47-year-old patient who had previous TV septal leaflet reconstruction using a bovine pericardial patch using 6/0 prolene, and an annuloplasty was performed by placing an annuloplasty ring in 2017 for infective endocarditis. The patient developed moderate to severe tricuspid regurgitation within a few weeks following the surgery. She was readmitted to the hospital four years later with a reduced consciousness level, and a subsequent repeat echocardiogram showed possible tricuspid valve vegetation. In addition, transoesophageal echocardiogram (TOE) demonstrated biventricular dysfunction and severe tricuspid regurgitation, along with moderate to severe mitral regurgitation (MR) that was variable depending on the rate of atrial fibrillation. The patient was not suitable for surgical intervention and was medically managed accordingly.

PMID:37469811 | PMC:PMC10352586 | DOI:10.7759/cureus.40497