Uniportal video-assisted thoracoscopic surgery pneumonectomy (U-VATS-P) is feasible and safe from a perioperative standpoint. How to choose the proper chest tube and drainage method is important in enhanced re… Read More
Category: General
Treatment of Aorto-iliac and Infrainguinal Vascular Infections with a Prefabricated Bovine Pericardial Graft
Ann Vasc Surg. 2024 Aug;105:177-188. doi: 10.1016/j.avsg.2024.01.015. Epub 2024 Apr 9.
ABSTRACT
BACKGROUND: The use of biological grafts provides acceptable mid- and long-term results in native or prosthetic vascular infections. Several reports describe the successful use of bovine pericardium in case of vascular infections, mainly as a large patch to be sutured as a tubular graft. Recently, a novel prefabricated bovine pericardium graft (Biointegral Surgical No-React® Inc, Mississauga, ON, Canada) has been introduced in clinical practice with promising results. In this study, we report our preliminary experience utilizing Biointegral Surgical graft in case of native and or prosthetic aorto-iliac and infrainguinal infection.
METHODS: We retrospectively analyzed data from 20 patients with native or prosthetic aorto-iliac and infrainguinal infection who underwent in situ reconstruction (ISR) with a Biointegral Surgical No-React bovine pericardium prosthesis between October 2020 and February 2023 at the Vascular Surgery Unit of the Fondazione Policlinico Universitario Gemelli – IRCCS in Rome, Italy. All patients followed a standardized protocol including postoperative anticoagulation and long-term intravenous antibiotics.
RESULTS: The indication for surgery was: mycotic aortic aneurysm in 4 patients (20%), graft infection after abdominal aortic repair in 11 patients (55%), peripheral graft infection in 5 patients (25%). Complete excision of the infected aorta or prosthetic graft, surgical debridement and ISR were performed in all patients. Hospital mortality rate was 5% (n = 1) and graft-related mortality of 0%. During follow-up (median 13 months, range 6-34 months), reinfection was 5.2% and primary graft patency 94.7%.
CONCLUSIONS: The use of prefabricated bovine pericardial grafts represents a promising option for the treatment of native and prosthetic aorto-iliac and infrainguinal infections. The application of this biological graft with a standardized postoperative protocol has been associated with a satisfactory patency and reinfection rate without increased bleeding complications.
PMID:38599483 | DOI:10.1016/j.avsg.2024.01.015
A case of posterior mediastinal myelolipoma and a literature review of its imaging manifestations
Mediastinal myelolipoma is a rare condition and has no obvious symptoms. In the past 20 years, some clinical cases have been documented. However, the literature has not systematically summarized its imaging fe… Read More
Correction: Influence of ABC stroke score on late recurrence of paroxysmal atrial fibrillation following radiofrequency catheter ablation
Aprotinin in high-risk isolated coronary artery bypass graft patients: a 3-year propensity matched study
Aprotinin, a serine protease inhibitor, has been used variably in cardiac surgery amidst ongoing debates about its safety following several previous studies. This study assesses the outcomes of aprotinin in hi… Read More
Outcomes after 4 years’ experience with low suction drains. Would it be safe to go drainless or low suction?
The principles of chest drainage have not changed significantly since 1875 when Bülau introduced the idea of underwater drainage tube which became a trademark of thoracic surgery. We performed a prospective, r… Read More
Correction: Influence of ABC stroke score on late recurrence of paroxysmal atrial fibrillation following radiofrequency catheter ablation
Analysis of risk factors for complications in echocardiography-guided percutaneous intramyocardial septal radiofrequency ablation
The feasibility of percutaneous intramyocardial septal radiofrequency ablation (PIMSRA) for the treatment of hypertrophic obstructive cardiomyopathy (HOCM) has been previously reported. However, limited invest… Read More
Rapid deployment aortic valve implantation in complex patients with infective endocarditis or aortic valve insufficiency
New prosthetic valves and surgical approaches that shorten operation time and improve the outcome of patients with aortic valve (AV) infective endocarditis (IE) and AV insufficiency (AVI) are crucial. The aim … Read More
Analysis of cardiac arrest after coronary artery bypass grafting
Cardiac arrest after coronary artery bypass grafting (CABG) is a serious complication with low survival rate. The prognosis of patients with cardiac arrest in the general ward is worse than that in the intensi… Read More
